Payne Multipoise Furnace, 96& AFUE, 60,000 BTU, Two-Stage, Variable Speed, 115/1

Item
PG96VTAA42060B
  • California Prop 65
The PG96VTA Multipoise Variable-Speed Condensing Gas Furnace features the two-stage gas valve and a variable speed, constant torque (VCT) ECM blower motor. With an Annual Fuel Utilization Efficiency (AFUE) up to 96.5% AFUE, the two-stage gas furnace provides exceptional savings when compared to standard gas furnaces. This Gas Furnace also features 4-way multipoise installation flexibility, and is available in nine model sizes. The PG96VTA can be vented for direct vent/two-pipe, ventilated combustion air, or single-pipe applications. All sizes are design certified in Canada. This furnace is not designed for use in recreation vehicles, manufactured (mobile) homes or out doors.

PERFORMANCE
• Variable-speed, constant-torque ECM blower motor, two-speed inducer motor, and two-stage gas valve.
• Aluminized-steel primary heat exchanger.
• Stainless-steel condensing secondary heat exchanger.
• Silicon Nitride Hot Surface Igniter.
• Adjustable blower speed for heating, cooling, continuous fan, and dehumidification.
INSTALLATION FLEXIBILITY
• 4-way multipoise design for upflow, downflow or horizontal installations, with unique vent elbow and optional through- the-cabinet downflow venting capability.
• Factory-configured ready for upflow applications.
• Installation flexibility: sidewall or vertical vent.
• Ideal height 35” (889 mm) cabinet: short enough for taller coils, but still allows enough room for  service.
• Direct-vent/sealed combustion, single-pipe venting or ventilated combustion air.
APPLICATIONS
• Convertible to propane with gas conversion accessory kit.
• Convenient Air Purifier and Humidifier connections.
• Twinning capable with accessory kit.
• 5 ton sizes allow 15 Amp breaker with assessory (order sparately).
CERTIFICATIONS
• All sizes meet ENERGY STAR® Version 4.1 criteria for gas furnaces: 95.0%+ AFUE.  
• Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193.
• All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.
Specification
Fuel Type Natural Gas (factory), Propane Gas
Stages Two Stages
Number of Burners 3
Maximum Pressure 13.6
Limit Control Range SPST
Ignition Type Silicon Nitride
Heat Exchanger Type Clam Shell
Gas Connection Size 1/2" - NPT
AFUE 96
CFM Heating 1135
CFM Cooling 1475
CFM 1400
BTU Output 58000
BTU Input 60000
Blower Wheel 11 X 8
Blower Speeds Variable
Blower Motor Type ECM
Blower Motor HP 3/4
Electrical
FLA 10.1
Hertz 60
MCA 10.9
MOCP 15
Phase 1
RLA 10.1
Voltage 115
Safety Standards
California Prop 65 Yes
Weights and Dimensions
Operating Weight (lbs) 139
Exterior Dimensions (D) (inches) 29.500000
Exterior Dimensions (W) (inches) 17.500000
Exterior Dimensions (H) (inches) 35.000000
Shipping Weight (lbs) 200.000000
General
Tier Payne