Payne Multipoise Furnace, 97% AFUE, 40,000 BTU, Two-Stage, Variable Speed, 115/1
Item
PG97VTAA36040B
The PG97VTA Multipoise two-stage Condensing Gas Furnace features a variable 25-speed constant-torque ECM motor. With an Annual Fuel Utilization Efficiency (AFUE) up to 97% AFUE, the two-stage gas furnace provides exceptional savings when compared to standard gas furnaces. This Gas Furnace also features 4-way multipoise installation flexibility, and is available in six model sizes. The PG97VTA can be vented for direct vent/two-pipe, ventilated combustion air, or single-pipe applications. All sizes are design certified in Canada. This furnace is not designed for use in recreation vehicles, manufactured (mobile) homes or out doors.
APPLICATIONS
• Dual Fuel Compatible
• Convertible to propane with gas conversion accessory kit
• Convenient Air Purifier and Humidifier connections
• Twinning capable with accessory kit
• 60080C, 60100C, and 66120D size allows 15 Amp breaker with accessory (order separately)
PERFORMANCE
• Variable 25-speed, constant-torque (VCT) ECM blower motor, two-speed inducer motor, and two-stage gas valve
• Aluminized-steel primary heat exchanger
• Stainless-steel condensing secondary heat exchanger
• Silicon Nitride Hot Surface Igniter
• Adjustable blower speed for heating, cooling, continuous fan, and dehumidification
INSTALLATION FLEXIBILITY
• 4-way multipoise design for upflow, downflow or horizontal installations, with unique vent elbow and optional through-the-cabinet downflow venting capability
• On-board NFC antenna makes setup a tap away when using the service technician app
• Factory-configured ready for upflow applications
• Installation flexibility: sidewall or vertical vent
• Ideal height 35" (889 mm) cabinet: short enough for taller coils, but still allows enough room for service
• Direct-vent/sealed combustion, single-pipe venting or ventilated combustion air
CERTIFICATIONS
• All sizes meet ENERGY STAR® Version 4.1 criteria for gas furnaces: 95%+ AFUE
• Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
• All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirement
LIMITED WARRANTY *
• Default 5-year parts limited warranty
• 20-year heat exchanger limited warranty
-10-year parts limited warranty with timely registration*
* Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration.
* Applies to original purchaser/homeowner and not available to subsequent owners. See warranty certificate for complete details and restrictions, including warranty coverage of other applications.
| Specification | |
|---|---|
| Fuel Type | Natural Gas (factory), Propane Gas | Stages | Two Stages | Gas Connection Size | 1/2" - NPT | Blower Speeds | Variable | Blower Motor Type | ECM |
| Electrical | |
|---|---|
| Hertz | 60 | MOCP | 15 | Phase | 1 | Voltage | 115 |
| Safety Standards | |
|---|---|
| California Prop 65 | Yes |
| Weights and Dimensions | |
|---|---|
| Operating Weight (lbs) | 133 | Exterior Dimensions (D) (inches) | 29.500000 | Exterior Dimensions (W) (inches) | 17.500000 | Exterior Dimensions (H) (inches) | 35.000000 | Shipping Weight (lbs) | 200.000000 |
| General | |
|---|---|
| Tier | Payne |