Payne 14 SEER Single Stage, Package Rooftop Gas Heat/Elect Cool, 208/1

Grouped product items
Product Name
Payne 3 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, 460/3
MFR:
Item:
PY4GEAB36060N
Payne 3.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, 460/3
MFR:
Item:
PY4GEAB42060N
Payne 5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, 460/3
MFR:
Item:
PY4GEAB60090N
Payne 2 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB24040N
Payne 2 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB24040NTP
Payne 2 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB24060NTP
Payne 2.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB30040N
Payne 2.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB30040NTP
Payne 2.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
PY4GNAB30060
Payne 2.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB30060N
Payne 2.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB30060NTP
Payne 3 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
PY4GNAB36060
Payne 3 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB36060N
Payne 3 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB36060NTP
Payne 3 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB36090N
Payne 3 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB36090NTP
Payne 3.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB42060N
Payne 3.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB42060NTP
Payne 3.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB42090N
Payne 3.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB42090NTP
Payne 4 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
PY4GNAB48090
Payne 4 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB48090N
Payne 4 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB48090NTP
Payne 5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
PY4GNAB60090
Payne 5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB60090N
Payne 5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/1
MFR:
Item:
PY4GNAB60090NTP
Payne 3 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/3
MFR:
Item:
PY4GPAB36060N
Payne 3.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/3
MFR:
Item:
PY4GPAB42060N
Payne 3.5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/3
MFR:
Item:
PY4GPAB42090N
Payne 4 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/3
MFR:
Item:
PY4GPAB48090N
Payne 5 Ton, 14 SEER, Package RTU Gas Heat/Elec Cool, Low NOX, 208/3
MFR:
Item:
PY4GPAB60090N

PY4G  Packaged Gas Furnace/Air Conditioner Combination 14

Enjoy the classic comfort combination of gas heating and electric air conditioning in one complete package. It's an efficient, durable and dependable solution for controlling indoor temperatures all year long with added humidity control during the summertime.
 
Single--Packaged Products with Energy--Saving Features and
R--410A refrigerant.
S 14.0 SEER
S 11.5 EER
S 81.0% AFUE (Single phase models)
S ECM Motor--Standard
S Direct Spark Ignition
S Low Sound Levels
S Dehumidification Feature
S Cabinet air leakage of 2.0% or less at .5 in. W.C. when tested in
accordance with ASHRAE standard 193. (Low leak FIOP models
only.)
FEATURES/BENEFITS
One--piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
Easy Installation
Factory--assembled package is a compact, fully self--contained,
combination gas heating/electric cooling unit that is prewired,
pre--piped, and pre--charged for minimum installation expense.
These units are available in a variety of standard and optional
heating/ cooling size combinations with voltage options to meet
residential and light commercial requirements. Units are
lightweight and install easily on a rooftop or at ground level. The
high tech composite base eliminates rust problems associated with
ground level applications.
Innovative Unit Base Design
On the inside a high--tech composite material will not rust and
incorporates a sloped drain pan which improves drainage and helps
inhibit mold, algae and bacterial growth. On the outside metal base
rails provide added stability as well as easier handling and rigging.
Convertible duct configuration
Unit is designed for use in either downflow or horizontal
applications. Each unit is converted from horizontal to downflow
and includes two horizontal duct covers. Downflow operation is
provided in the field to allow vertical ductwork connections. The
basepan seals on the bottom openings to ensure a positive seal in
the vertical airflow mode.
Efficient operation High--efficiency design offers SEER
(Seasonal Energy Efficiency Ratios) of 14.0, 11.5 EER, and
AFUE (Annual Fuel Utilization Efficiency) ratings up to 81.0%.
Energy--saving, direct spark ignition saves gas by operating only
when the room thermostat calls for heating. Standard units are
furnished with natural gas controls. A low--cost field installed kit
for propane conversion is available for all units.
Low NOx units are designed for California installations and meet
40 ng/J NOx emissions. Can be installed in air quality management
districts with a 40 ng/J NOx emissions requirement.
Durable, dependable components
Monoport inshot burners produce precise air--to--gas mixture,
which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if ever,
requires cleaning. All gas furnace components are accessible in one
compartment.
Turbo--tubulart heat exchangers are constructed of aluminized
steel for corrosion resistance and optimum heat transfer for
improved efficiency. The tubular design permits hot gases to make
multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force the
hot gases to stay in close contact with the walls, improving heat
transfer.
ECM Motor is standard on all models.
Direct--drive PSC (Permanent Split Capacitor) condenser--fan
motors are designed to help reduce energy consumption and
provide for cooing operation down to 40_F (4.4_C) outdoor
temperature. Motormasterr II low ambient kit is available as a
field--installed accessory.