Legacy™ 14 SEER, Single Stage, Package Rooftop Gas Heat/ Elect Cool

  • California Prop 65
Grouped product items
Product Name
Bryant 2.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWF30040NTP
Bryant 3 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, Ultra-Low NOx (SCAQMD/SJVAPCD Compliant), 208/1
MFR:
Item:
577CNWE36060UTP
Bryant 4 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, Ultra-Low NOx (SCAQMD/SJVAPCD Compliant), 208/1
MFR:
Item:
577CNWE48090UTP
Bryant 5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, Ultra-Low NOx (SCAQMD/SJVAPCD Compliant), 208/1
MFR:
Item:
577CNWE60090UTP
Bryant 2 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, Ultra-Low NOx (SCAQMD/SJVAPCD Compliant), 208/1
MFR:
Item:
577CNWE24060UTP
Bryant 3.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, Ultra-Low NOx (SCAQMD/SJVAPCD Compliant), 208/1
MFR:
Item:
577CNWE42060UTP
Bryant 2.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, Ultra-Low NOx (SCAQMD/SJVAPCD Compliant), 208/1
MFR:
Item:
577CNWF30060UTP
Bryant 2 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE24040
Bryant 3 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE36060
Bryant 3 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE36090
Bryant 3.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE42090
Bryant 4 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE48090
Bryant 5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE60090
Bryant 5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE60115
Bryant 3.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE42090TP
Bryant 2 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE24060TP
Bryant 2.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE30060TP
Bryant 3 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE36060TP
Bryant 3.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE42060TP
Bryant 4 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE48090TP
Bryant 5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE60090TP
Bryant 5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE60130TP
Bryant 2 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE24040NTP
Bryant 2.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE30060NTP
Bryant 3 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE36060NTP
Bryant 2 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE24060NTP
Bryant 3 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE36090NTP
Bryant 3.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE42060NTP
Bryant 3.5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE42090NTP
Bryant 4 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE48090NTP
Bryant 5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE60090NTP
Bryant 5 Ton, 14 SEER, Legacy Package RTU Gas Heat/Elec Cool, 208/1
MFR:
Item:
577CNWE60115NTP

Features/Benefits

One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. Puron® is Bryant’s unique refrigerant designed to be environmentally balanced. Puron® is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. The most important advantage of Puron® refrigerant is that it has not been banned in future air conditioning systems as the traditional refrigerant R-22 has been. Puron® refrigerant is in service in millions of systems proving highly reliable and is non-ozone depleting.

Easy Installation

Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/ cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications.

Innovative Unit Base Design

On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging.

Convertible duct configuration

Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is  provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode.

Efficient operation

High-efficiency design offers SEER (Seasonal Energy Efficiency Ratios) of 14.0, 11.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings up to 81.0%.

Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units.

Low NOx units are designed for California installations and meet 40ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.

Durable, dependable components

Monoport inshot burners produce precise air-to-gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment.

Turbo-tubular™ heat exchangers are constructed of aluminized steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air. In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer.

ECM Motor is standard on all models.

Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40°F (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field installed accessory.

Thermostat controls

Time Guard® II anti-short cycle protection circuitry. If a non-corporate thermostat without anti-short cycle protection is used the Time Guard® II field-installed anti-short cycle kit is recommended.

Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leavesthe factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier.

High Pressure Switch provides added reliability for the compressor.

Indoor and Outdoor coils are computer-designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit.

Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 72dBA.

Easy to service cabinets provide easy 3-panel accessibility to serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level installation with mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4-in. (19.05 mm) wide perimeter flange makes frame mounting on a rooftop easy.

Standard horizontal metal duct covers with insulation come with the unit and cover the horizontal duct openings. These can be left in place if the units are converted to downflow.

Integrated Gas Control (IGC) board provides safe and efficient control of heating and simplifies trouble-shooting through its built-in diagnostic function.

Cabinets are constructed of heavyduty, phosphated, zinc-coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator/heat exchanger compartment are insulated with cleanable semi-rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers 62.2.) The sloped drain pan minimizes standing water in the drain. An external drain is provided.