Carrier Infinity Multipoise Furnace, 95% AFUE, 100,000 BTU, Single-Stage Heating, Variable Speed, Ultra Low Nox (SCAQMD/SJVAPCD/BAAQMD Compliant), 115/1

Item
59CU5B100C2122
  • California Prop 65
The 59CU5B Infinity® Ultra-Low NOx gas furnace delivers consumer comfort in a unit that meets California’s South Coast Air Quality Management District (SCAQMD) and San Joaquin Valley Air pollution Control District (SJVAPCD) NOx emissions limit of 14ng/J. Offering the performance and benefits of our Infinity Series gas furnaces, this furnace releases 65% less nitrogen oxides (NOx) than previous models. NOx contributes to the formation of smog and acid rain and the deterioration of water quality. Lower NOx emissions mean lower production of particulate matter and cleaner air for the environment. Energy efficiency is at the heart of this furnace with up to 95.0% AFUE gas efficiency and the electrically-efficient Infinity communicating variable-speed constant airflow ECM blower motor. This gas furnace also features Upflow/Horizontal installation flexibility, and is available in three model sizes. All sizes can be vented for direct vent/two-pipe, ventilated combustion air, or single-pipe applications.

PERFORMANCE
• Communicating Variable speed, Constant airflow (VCA) ECM blower motor for electrically efficient operation all year long in heating, cooling and continuous fan operation.
• Single-stage gas valve with pre-mix burner
• Pilot free, hot surface ignition
• Variable-speed inducer motor for consistent operation
• Supports single-stage, two-stage, and variable speed cooling units
• High temperature limit control designed to prevent overheating
• Adjustable blower speed for heating, cooling, continuous fan, anddehumidification
• Stainless-steel primary heat exchanger
• Fully-insulated casing including blower section
• Stainless-steel condensing secondary heat exchanger INSTALLATION FLEXIBILITY
• Upflow/Horizontal design for upflow, horizontal right or horizontal left installation, with rotating vent elbow for exhaust venting flexibility
• Factory-configured ready for upflow applications.
• Features a condensate trap with 6-3/8" (7-3/8" recommended) clearance in horizontal applications
• Ideal height 35" (889 mm) cabinet: short enough for taller coils, but still allows enough room for service.
• Two-pipe venting, single-pipe venting or ventilated combustion air.

APPLICATIONS
• Factory-configured for Natural Gas; not convertible to Liquid Propane.
• Not approved for downflow installation
• Approved for installations up to 5,400 ft.

CERTIFICATES
• All sizes meet ENERGY STAR® Version 4.1 criteria for gas furnaces: 95%+ AFUE
• Ultra Low NOx – meets the nitrogen oxides (NOx) emission limit of 14 nanograms/joule for the South Coast Air Quality Management District and San Joaquin Valley Air Pollution Control District in California
• Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193.

 

Specification
Fuel Type Natural Gas Only
Stages Single Stage
Ignition Type Silicon Nitride Hot Surface
Heat Exchanger Type Stainless Steel Tubular
Gas Connection Size 1/2 - NPT
Electrical
Hertz 60
MCA 14.3
MOCP 20
Phase 1
Voltage 115
Safety Standards
California Prop 65 Yes
Weights and Dimensions
Operating Weight (lbs) 180
Exterior Dimensions (D) (inches) 29.500000
Exterior Dimensions (W) (inches) 21.000000
Exterior Dimensions (H) (inches) 35.000000
Shipping Weight (lbs) 180.000000
Warranty
Parts Warranty 10 Year (When Registered in Residential Application)
General
Tier Infinity